N2011 Multi Use Standalone Temperature Data Logger
The N2011 Multi-Use Temperature Data Logger allows easy monitoring of temperature sensitive systems, in transit or in storage.
Complying with EN12830:1999 standard, it is perfectly suited for cold chain applications.
- Temperature Range: -40°C to +70°C / -40°F to +158°F.
- Complies with Cold Chain EN12830:1999 standard.
- Battery Life up to 5 Years.
- Warranty: 2 Years.
Easy monitoring of temperature sensitive products in transit and storage.
- Tested to meet EN12830:1999 making it particularly suitable for cold chain applications.
- One of the range of Diligence EV data loggers, N2011 is also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems.
- Requires dedicated software.
The N2011 requires dedicated software and a computer interface N2000CRUSB to download data to a PC.
Two versions of software are available.
- EVSW for general use and ideal for HACCP and other quality systems.
- EVSWPRO which aids compliance with 21CFR Part 11.
The new EV Software can be downloaded from the Comark Software download page. To download the software, you must have or create a Comark Website account.
- Internal sensor with measurement range -40°C/-40°F to 70°C/ 158°F
- LCD Display for temperature readings and alarm indication
- Tough, moulded case, dust and waterproof to IP67 standards
- Large memory capacity of up to 16000 readings
- Ability to log over multiple periods
- Single, multi-function button
- LED indicators to show active logging and alarm conditions, plus audible alarm warning
- Temperature system accuracy, suitable for food industry applications
- Long battery life
- Two year warranty
- First Time Buyers should Purchase the N2011 Starter Kit
Download Literature
EV Software Guide for N2011N Series Data Logger Literature
- Sensor Type Thermistor
- Measurement Range -40°C to +70°C/-40°F to +158°F
- Scales °C and °F
- Display Resolution 0.1°
- --------------------------------------------------------------------------------
- System Accuracy °C
- -25°C to +50°C ±0.5°C
- -40°C to +70°C ±1°C
- --------------------------------------------------------------------------------
- System Accuracy °F
- -13°F to +122°F ±1°F
- -40°F to +158°F ±2°F
- --------------------------------------------------------------------------------
- Memory 32K 16000 samples
- Communications Via infra red interface
- Download Time 3 minutes for 10, 000 readings (typical)
- Logging Frequency Programmable between 1 second and 99 hours
- Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
- --------------------------------------------------------------------------------
- Ambient Storage -40°C to +70°C/-40°F to +158°F
- Logging Start Programmable date and time or manual start from instrument multi-function button
- Software Windows™ based software for Windows XP or Vista
- --------------------------------------------------------------------------------
- Battery Type 1 x AA size 3.6V replaceable lithium battery
- Battery Life Up to 5 years
- Case Material ABS
- Environmental Protection IP67 BS EN 60529 IEC 529
- --------------------------------------------------------------------------------
- LED Indication
- Red Alarm
- Green Logger Active
- --------------------------------------------------------------------------------
- Dimensions
- Length 88mm/3.5ins (including fixing lug)
- Width 80mm/3.1ins
- Depth 35mm/1.4insSensor Type Thermistor
- Measurement Range -40°C to +70°C/-40°F to +158°F
- Scales °C and °F
- Display Resolution 0.1°
- --------------------------------------------------------------------------------
- System Accuracy °C
- -25°C to +50°C ±0.5°C
- -40°C to +70°C ±1°C
- --------------------------------------------------------------------------------
- System Accuracy °F
- -13°F to +122°F ±1°F
- -40°F to +158°F ±2°F
- --------------------------------------------------------------------------------
- Memory 32K 16000 samples
- Communications Via infra red interface
- Download Time 3 minutes for 10, 000 readings (typical)
- Logging Frequency Programmable between 1 second and 99 hours
- Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
- --------------------------------------------------------------------------------
- Ambient Storage -40°C to +70°C/-40°F to +158°F
- Logging Start Programmable date and time or manual start from instrument multi-function button
- Software Windows™ based software for Windows XP or Vista
- --------------------------------------------------------------------------------
- Battery Type 1 x AA size 3.6V replaceable lithium battery
- Battery Life Up to 5 years
- Case Material ABS
- Environmental Protection IP67 BS EN 60529 IEC 529
- --------------------------------------------------------------------------------
- LED Indication
- Red Alarm
- Green Logger Active
- --------------------------------------------------------------------------------
- Dimensions
- Length 88mm/3.5ins (including fixing lug)
- Width 80mm/3.1ins
- Depth 35mm/1.4ins