N2011 Multi Use Standalone Temperature Data Logger

€202.00
-
+
€202.00

The N2011 Multi-Use Temperature Data Logger allows easy monitoring of temperature sensitive systems, in transit or in storage.

Complying with EN12830:1999 standard, it is perfectly suited for cold chain applications.

  • Temperature Range: -40°C to +70°C / -40°F to +158°F.
  • Complies with Cold Chain EN12830:1999 standard.
  • Battery Life up to 5 Years.
  • Warranty: 2 Years.


Easy monitoring of temperature sensitive products in transit and storage.

  • Tested to meet EN12830:1999 making it particularly suitable for cold chain applications.
  • One of the range of Diligence EV data loggers, N2011 is also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems.
  • Requires dedicated software.

The N2011 requires dedicated software and a computer interface N2000CRUSB to download data to a PC.

Two versions of software are available.

  • EVSW for general use and ideal for HACCP and other quality systems.
  • EVSWPRO which aids compliance with 21CFR Part 11.
The Software interface has been redesigned and the software upgraded to be fully compliant with Microsoft Windows 10.

The new EV Software can be downloaded from the Comark Software download page. To download the software, you must have or create a Comark Website account.
    N2011 Data Logger
    • Internal sensor with measurement range -40°C/-40°F to 70°C/ 158°F
    • LCD Display for temperature readings and alarm indication
    • Tough, moulded case, dust and waterproof to IP67 standards
    • Large memory capacity of up to 16000 readings
    • Ability to log over multiple periods
    • Single, multi-function button
    • LED indicators to show active logging and alarm conditions, plus audible alarm warning
    • Temperature system accuracy, suitable for food industry applications
    • Long battery life
    • Two year warranty
    • First Time Buyers should Purchase the N2011 Starter Kit

    Download Literature

        EV Software Guide for N2011

        N Series Data Logger Literature

    • Sensor Type Thermistor
    • Measurement Range -40°C to +70°C/-40°F to +158°F
    • Scales °C and °F
    • Display Resolution 0.1°
    • --------------------------------------------------------------------------------
    • System Accuracy °C
    • -25°C to +50°C ±0.5°C
    • -40°C to +70°C ±1°C
    • --------------------------------------------------------------------------------
    • System Accuracy °F
    • -13°F to +122°F ±1°F
    • -40°F to +158°F ±2°F
    • --------------------------------------------------------------------------------
    • Memory 32K 16000 samples
    • Communications Via infra red interface
    • Download Time 3 minutes for 10, 000 readings (typical)
    • Logging Frequency Programmable between 1 second and 99 hours
    • Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
    • --------------------------------------------------------------------------------
    • Ambient Storage -40°C to +70°C/-40°F to +158°F
    • Logging Start Programmable date and time or manual start from instrument multi-function button
    • Software Windows™ based software for Windows XP or Vista
    • --------------------------------------------------------------------------------
    • Battery Type 1 x AA size 3.6V replaceable lithium battery
    • Battery Life Up to 5 years
    • Case Material ABS
    • Environmental Protection IP67 BS EN 60529 IEC 529
    • --------------------------------------------------------------------------------
    • LED Indication
    • Red Alarm
    • Green Logger Active
    • --------------------------------------------------------------------------------
    • Dimensions
    • Length 88mm/3.5ins (including fixing lug)
    • Width 80mm/3.1ins
    • Depth 35mm/1.4insSensor Type Thermistor
    • Measurement Range -40°C to +70°C/-40°F to +158°F
    • Scales °C and °F
    • Display Resolution 0.1°
    • --------------------------------------------------------------------------------
    • System Accuracy °C
    • -25°C to +50°C ±0.5°C
    • -40°C to +70°C ±1°C
    • --------------------------------------------------------------------------------
    • System Accuracy °F
    • -13°F to +122°F ±1°F
    • -40°F to +158°F ±2°F
    • --------------------------------------------------------------------------------
    • Memory 32K 16000 samples
    • Communications Via infra red interface
    • Download Time 3 minutes for 10, 000 readings (typical)
    • Logging Frequency Programmable between 1 second and 99 hours
    • Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
    • --------------------------------------------------------------------------------
    • Ambient Storage -40°C to +70°C/-40°F to +158°F
    • Logging Start Programmable date and time or manual start from instrument multi-function button
    • Software Windows™ based software for Windows XP or Vista
    • --------------------------------------------------------------------------------
    • Battery Type 1 x AA size 3.6V replaceable lithium battery
    • Battery Life Up to 5 years
    • Case Material ABS
    • Environmental Protection IP67 BS EN 60529 IEC 529
    • --------------------------------------------------------------------------------
    • LED Indication
    • Red Alarm
    • Green Logger Active
    • --------------------------------------------------------------------------------
    • Dimensions
    • Length 88mm/3.5ins (including fixing lug)
    • Width 80mm/3.1ins
    • Depth 35mm/1.4ins

    Recently Viewed Products